MIL-DTL-22442/30B(AS)
APPLICABLE DOCUMENTS:
APPLICABLE DRAWINGS
AIR FORCE
57Bl2662
-
Connector, Plug Electrical U-l73/U
57Bl2664
-
Tip - Electrical, Plug Connector
REQUIREMENTS:
l. The cable (cord) shall be in accordance with M22442/35-2.
2. The weight of the cable assembly shall not be greater than 6 ounces.
3. The stay cord shall be firmly attached to the connectors.
4. The following parts shall be supplied in a plastic bag with each cable:
(a) One P/N M22442/32-5 nut, tee.
(b) One P/N M22442/32-6 screw, visor housing.
(c) One P/N M22442/32-7 clip, cable.
5. The P/N M22442/30-l cable assembly shall terminate in a P/N M22442/5-2 connector
and the P/N M22442/30-2 cable assembly shall terminate in a P/N M22442/5-l (U-75/U)
connector.
6. The DC resistance of the P/N M22442/30-l cable assembly shall be as indicated when
tested with an ohmmeter.
(a) Contact l of U-l72/U and contact l of P/N M22442/5-2 less than 2 ohms.
(b) Contact 2 of U-l72/U and contact 3 of P/N M22442/5-2 less than 2 ohms.
(c) Contact 1 of U-l73/U and contact 2 of U-l73/U less than 10 ohms.
(d) Contact 2 of P/N M22442/5-2 and contact 4 of P/N M22442/5-2 less than l00
ohms.
7. The DC resistance of the P/N M22442/30-2 cable assembly shall be less than 2 ohms
between the following contacts:
(a) Contact l of U-173/U and contact 2 of P/N M22442/5-1 (U-75/U).
3