MIL-DTL-22442/19D(AS)
(b). Terminal "B" and contact 2 of P/N M642/l4-0l (U-384/U) less than 2 ohms.
(c) Terminal "C" and contact 3 of P/N M642/l4-0l (U-384/U) less than 2 ohms.
(d). Terminals "D" and "E" and contact 5 of P/N M642/14-0l (U-384/U) less than
2 ohms.
(e). Terminal "F" and contact 4 of P/N M642/l4-0l (U-384/U) less than 2 ohms.
8. The cable assembly shall be tested in accordance with the tests listed in Table I.
*9. The 2 6-32 UNC mounting nuts shall withstand a minimum of 6 inch-pounds of
torque out force. This test shall be in accordance with Group III sampling testing.
NOTES:
l. All dimensions are in inches.
2. Tolerances are:
Metal parts ±.005
Molded sections ±.05 inches unless otherwise specified.
3. MIL-C-8l864 is superseded by MIL-DTL-22442/l9.
4. Mylar identification plates may be used as an alternate method.
CHANGES FROM PREVIOUS ISSUE: The margins of this specification are marked with
asterisks to indicate where changes from the previous issue were made. This was done as a
convenience only and the Government assumes no liability whatsoever for any inaccuracies in
these notations. Bidders and contractors are cautioned to evaluate the requirements of this
document based on the entire content irrespective of the marginal notations and relationship to the
last previous issue.
Preparing activity:
Navy - AS
(Project No. 5995-0128-05)
3