MIL-DTL-22442/26E(AS)
REQUIREMENTS:
l. The M22442/26-3 cable assembly consists of one M22442/26-l cable and one
M22442/26-2 cable.
*2. The cable (cord) for the M22442/26-l cable assembly shall be in accordance with
M22442/35-l. The cable (cord) for the M22442/26-2 cable shall be in accordance with
M22442/35-1 with the black and white conductors only. The electrostatic and
electromagnetic isolation requirements of M22442/35-1 and -2 are not required.
3. The weight of the cable assembly shall not be greater than 6 ounces.
4. The stay cord shall be firmly attached to the connectors.
5. The DC resistance for P/N M22442/26-l shall be as indicated when tested with an
ohmmeter.
(a) Contact l of U-l79/U and contact l of P/N M22442/5-2 less than 2 ohms.
(b) Contact 2 of U-l79/U and contact 3 of P/N M22442/5-2 less than 2 ohms.
(c) Contact l of U-l73/U and contact 2 of U-l73/U less than l0 ohms.
(d) Contact 2 of P/N M22442/5-2 and contact 4 of P/N M22442/5-2 less than
100 ohms.
6. The DC resistance for P/N M22442/26-2 shall be less than 2 ohms between the
following contacts when tested with an ohmmeter.
(a) Contact l of U-l73/U and contact l of U-l72/U.
(b) Contact 2 of U-l73/U and contact 2 of U-l72/U.
7. The "X" dimension shall be 42.25 +3 -5 before coiling.
8. The cable assembly shall be tested in accordance with the applicable tests listed in
table I.
NOTES:
l. All dimensions are in inches.
2. Tolerances are metal parts ±.005, molded sections ±.05 inches unless otherwise
specified.
3. This specification sheet supersedes Naval Air Systems Command Drawing 765AS285.
3