MIL-DTL-22442/33B
TABLE I. Tests
Inspection
Requirement Test
Group I
Group II
Group III
Paragraph
Paragraph
Qualification Quality
Sample
Tests
Conforma
Testing Per
nce
4.4.1
Test 100%
GROUP A
(ALL SAMPLE UNITS)
1/
Visual & Mechanical
3.1 & 3.4
4.5.2
X
X
Inspection
Soldering
3.4.18
4.5.2.1
X
X
Continuity
3.5.1
4.5.3
X
X
GROUP B
Electrostatic and Electro-
Req. 8
Req. 8
X
X
magnetic Isolation
Dielectric Withstanding
3.5.2
4.5.4
X
X
Voltage
Pull and Twist Test 1/
3.5.4
4.5.6
X
X
Bend Relief Flexibility
3.5.5
4.5.7
X
X
Durometer Hardness
3.5.10
4.5.12
X
X
GROUP C
Low Temperature
3.5.6
4.5.8
X
X
Flexibility
Durability 1/
3.5.7
4.5.9
X
X
Ozone Resistance 1/
3.5.8
4.5.10
X
X
Jacket Elongation
3.5.9
4.5.11
X
X
GROUP D 1/
Temperature-Altitude 2/
3.6.1
4.6.1
X
Salt Fog
3.6.2
4.6.2
X
Humidity
3.6.5
4.6.5
X
Thermal Shock
3.6.5
4.6.6
X
l/
Minimum tests for QPL retention (see paragraph 4.3.3)
2/
Steps 3 and 12 only
4