MIL-DTL-22442/12C
APPLICABLE DOCUMENTS
MS3116
-
Connector, Plug, Electric
REQUIREMENTS:
1. The cable shall be in accordance with MIL-DTL-22442/3.
2. Connector "X" shall be MS3116F10-6P or functional equivalent. Black tubing may be used as a
bushing under strain relief.
3. The weight of the cable assembly shall not be greater than 10 ounces.
4. The stay cord shall be firmly attached to the connectors.
5. The DC resistance shall be less than 2 ohms between the following contacts when tested with an
ohmmeter.
(a) Contact A of ."X" and contact 4 of P/N M22442/4-1.
(b) Contact B of "X" and contact 2 of P/N M22442/4-1.
(c) Contact C of "X" and contact 4 of P/N M22442/4-1.
(d) Contact D of "X" and contact 1 of P/N M22442/4-1.
(e) Contact E of "X" and contact 3 of P/N M22442/4-1.
6. The cable assembly shall be tested in accordance with the tests listed in Table I.
NOTES:
1. All dimensions are in inches.
2. Tolerances are metal parts +.005, molded sections +.05 inches unless otherwise specified.
Preparing activity:
Navy AS
(Project No. 5995-0128-32)
2