MIL-DTL-22442/12C
TABLE I. Tests
Inspection
Requirement
Test
Group I
Group II
Group III
Sample
Paragraph
Paragraph
Qualification
Quality
Tests
Conformance
Testing
100% Per
Tests
4.5.1
GROUP A (ALL
SAMPLE UNITS) 1/
Visual & Mechanical
3.1 & 3.4
4.6.2
X
X
Inspection
Soldering
3.4.24
4.6.2.1
X
X
Continuity
3.5.3
4.6.5
X
X
GROUP B
Dielectric Withstanding
3.5.5
4.6.7
X
X
Voltage
Pull Test 1/
3.5.7
4.6.9
X
X
GROUP C
Durability 1/
3.5.13
4.6.15
X
X
Ozone Resistance 1/
3.5.14
4.6.16
X
X
Jacket Elongation
3.5.15
4.6.17
X
X
GROUP D 1/
Temperature-Altitude 2/
3.6.1
4.7
X
Salt Fog
3.6.2
4.7
X
Vibration
3.6.5
4.7
X
Shock
3.6.6
4.7
X
Humidity
3.6.6
4.7
X
Thermal Shock
3.6.6
4.7
X
1/ Minimum tests for QPL retention (see paragraph 4.4.4)
2/ Steps 3 and 12 only