MIL-DTL-3885G
AMERICAN SOCIETY FOR QUALITY (ASQ)
ASQ Z1.4
- Sampling Procedures and Tables for Inspection by
Attributes
(Copies of this document are available online at https://www.asq.org/ or from American Society of
Quality, 600 North Plankinton Avenue, Milwaukee, WI 53203.)
SAE INTERNATIONAL
SAE AS5942
- Marking of Electrical Insulating Materials
SAE AMS-DTL-23053/5
- Insulation Sleeving, Electrical, Heat Shrinkable,
Polyolefin, Flexible, Crosslinked
(Copies of these documents are available online at https://www.sae.org/ or from SAE International,
400 Commonwealth Drive, Warrendale, PA 15096-0001.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of
a conflict between the text of this document and the references cited herein, the text of this
document takes precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Detail requirements. The individual cable assemblies shall comply with all the
requirements specified herein as well as those cited on the applicable detail specification,
specification sheet, or drawing (see 6.2). In the event of a conflict between the requirements of
this specification and other requirements of the applicable device specification, the precedence in
which requirements shall govern, in descending order, is as follows:
a. Applicable device specification (detail specification or drawing).
b. This specification.
c. Specifications, standards, and other documents referenced in section 2.
3.2 First article. When specified (see 6.2), a sample shall be subjected to first article
inspection in accordance with 4.2. First article inspection shall consist of all tests specified
herein, and shall include materials inspection (see 4.2.1). Tests for insulation resistance and
dielectric-withstanding voltage shall be performed manually and the insulation resistance
3.3 Material. The material shall be specified in the applicable specification or drawing.
However, when a definite material is not specified, a material shall be used which will enable the
cable assembly to meet the performance requirements of this specification and shall be submitted
to the contracting officer for approval. Acceptance or approval of any constituent material shall
not be construed as a guarantee of the acceptance of the finished product (see 4.2.1).