MIL-DTL-22442G
ONE HALF HOUR FUNCTIONAL LEVEL FOLLOWED BY ONE HOUR ENDURANCE LEVEL
FOLLOWED BY ONE HALF HOUR FUNCTIONAL LEVEL IN EACH OF THREE MUTUALLY
PERPENDICULAR AXIS
Frequency
Frequency
Endurance Level
Endurance
Functional
Functional
(g2/Hz)
Level
Level
Level
(g2/Hz)
(g2/Hz)
(g2/Hz)
(Hz)
(Hz)
5
.005
.01
140
.08
.16
10
.04
.08
200
.02
.06
15
.05
.10
775
--
.06
20
.05
.10
825
.02
--
25
.04
.08
1000
.026
.087
30
.05
.14
1300
.026
.087
60
.05
.14
1400
.01
.043
65
.08
.16
2000
.005
.043
FUNCTIONAL LEVEL 6.45 grams
ENDURANCE LEVEL 12.0 grams
FIGURE 2. Functional and endurance vibration levels.