MIL-DTL-22442G
a. Cable assemblies shall be clamped and suspended in the vertical position with the "Y"
junction/crotch securely clamped at the flexure point and will not turn or twist during flexing.
Figure 1 is a typical test setup.
b. A one pound weight shall be attached to each leg of the "Y" junction/crotch. The legs
shall be positioned so that they are spread open 60 degrees, 30 degrees either side of vertical.
c. The cable assembly shall be rotated about the longitudinal axis through the point were the
legs emerge from the fixture. The fixture shall be rotated through an angle of 120 degrees,
60 degrees either side of vertical at a flexing rate of 85 cycles per minute for 25,000 cycles
without electrical discontinuity. After completion of this test the cable assembly shall meet the
requirements of 3.5.1 and 4.5.3. The "Y" junction/crotch shall be then cut open an inspected for
compliance with 3.4.18 and 4.4.2.1.