MIL-DTL-22442G
designed to protect, and shall not cause corrosion or deterioration of adjacent metal or plastic
parts.
3.4.17 Cementing compounds. Any cementing compound used in the construction of the
cable assembly shall withstand all service conditions including test conditions outlined in section
4 of this specification without evidence of loosening or otherwise affecting the performance
requirements of the cable assembly.
3.4.18 Soldering. Cable assemblies shall be soldered in accordance with J-STD-001, class 3.
3.4.19 Printed wiring boards. Printed wiring boards shall be designed in accordance with
IPC-2221 and IPC-2222.
3.5 Performance. The cable assembly shall meet the following performance requirements
when applicable.
3.5.1 Continuity. Each conductor shall be continuous in the assembly through the
terminations of the conductors, where the design calls for a continuous line. Testing shall be in
accordance with 4.5.3.
3.5.2 Dielectric withstanding voltage. Unless otherwise specified in the specification sheet,
the cable assemblies shall be capable of withstanding a dielectric withstanding voltage as
specified in the applicable cordage specification for a minimum of 30 seconds when tested in
accordance with 4.5.4.
3.5.3 Gauging. For connector terminated cable assemblies, contacts and interfacial
dimensions shall not be changed by the assembly procedure to prevent intermating of
connectors. Testing shall be in accordance with 4.5.5.
3.5.4 Pull and twist. The terminal components including metallic terminals, taper pins,
connectors, terminal blocks, and molded bend reliefs shall not part from the conductor at the
specified loads in accordance with the applicable drawings or specification sheets. After
twisting and pulling in accordance with 4.5.6, there shall be no more than 1/32 inch slippage of
the cable jacket from the connector, nor separation of the bond on molded terminations, molded
bend reliefs, and molded strain reliefs.
3.5.5 Bend relief, "Y" junction/crotch flexibility (see 6.5). For flexible molded cable
assemblies with bend relief's, or "Y" junction/crotch's there shall be no electrical discontinuity,
bond separation, or cracking between the insulation or bend relief and the cable jacket after
being tested in accordance with 4.5.7 or 4.5.7.1. The test specified in 4.5.7.1 is required only for
cable assemblies that are spliced at the "Y" junction/crotch.